Copyright © Siemens AG 2016. All rights reserved
153
ERTEC 200P-2 Manual
Technical data subject to change
Version 1.0
0 = no Error, 1 = AHB Error Response
occurred
11dt7 ERR_AHB_JOB_NR
00h
rh
AHB Master Interface Error JOB number
12dt12 ERR_JOB_START
0h
rh w
Hardware start of Job occurred befor
Job is finished (write 1 to clear)
0 = no Error, 1 = Error
17dt13 ERR_JOB_START_JOB_NR 00h
rh
Hardware start of Job occurred befor
Job is finished JOB number
18dt18 ERR_AHB_SLV_WRITE
0h
rh w
8 or 16 bit write access on AHB slave
interface (write 1 to clear)
0 = no Error, 1 = not allowed write
19dt19 ERR_AM_HOLD
0h
rh w
Addressmode of Source or Destination
address is HOLD and ESIZE and ad-
dress are not aligned (write 1 to clear)
0 = no Error, 1 = Error
24dt20 ERR_AM_HOLD_JOB_NR 00h
rh
ERR_AM_HOLD JOB number
31dt25 <notused>
00h
r
all bits
= '0'
Register:
GDMA_JOB_COUNT
Address:
A4h
Bits:
31dt0
Reset value:
00000000h
Attributes: rh
Description:
Counts clock cycles, when selected Jobs are active. Selection of the
counted Jobs is done through the GDMA_JC_EN register. Each Job
has own enable bit here. The reset of Job Counter is done through
“Reset Job Counter” flag of the GDMA_MAIN_CTRL register.
Register:
REVISION_CODE
Address:
A8h
Bits:
15dt0
Reset value:
0101h
Attributes: r
Description:
Revison Code register
Bit
Identifier
Reset
Attr. Function
/
Description
7dt0 MINOR_REVISION
01h
r
minor revision
= 0x1
15dt8 MAJOR_REVISION
01h
r
major revision
= 0x1