Copyright © Siemens AG 2016. All rights reserved
195
ERTEC 200P-2 Manual
Technical data subject to change
Version 1.0
Register:
XHIF_1_P0_CFG
Address:
C8h
Bits:
0dt0
Reset value:
0h
Attributes: r w
Description:
Configuration of the buffering mode for page #0
Bit
Identifier
Reset
Attr.
Function / Description
0
XHIF_1_P0_CFG_BUFMOD 0h
r w 16bit access mode of page #0
Register:
XHIF_1_P1_RG
Address:
D0h
Bits:
31dt0
Reset value:
0h
Attributes: r (w)
Description:
Range value of the page #1
Bit
Identifier
Reset
Attr.
Function / Description
7dt0 XHIF_1_P1_RG_ROSL2 00h
r
Read only value = 0
21dt8 XHIF_1_P1_RG_RW
0000h
r w Read/Write part of the Range regis-
ter
31dt22 XHIF_1_P1_RG_ROSL1 000h
r
Read only value = 0
Register:
XHIF_1_P1_OF
Address:
D4h
Bits:
31dt0
Reset value:
0h
Attributes: r (w)
Description:
Offset value of the page #1
Bit
Identifier
Reset
Attr.
Function / Description
7dt0 XHIF_1_P1_OF_RO
00h
r
Read only value = 0
31dt8 XHIF_1_P1_OF_RW
000000h r w Read/Write value of the offset regis-
ter
Register:
XHIF_1_P1_CFG
Address:
D8h
Bits:
0dt0
Reset value:
0h
Attributes: r w
Description:
Configuration of the buffering mode for page #1
Bit
Identifier
Reset
Attr.
Function / Description
0
XHIF_1_P1_CFG_BUFMOD 0h
r w 16bit access mode of page #1
Register:
XHIF_1_P2_RG
Address:
E0h
Bits:
31dt0
Reset value:
0h
Attributes: r (w)
Description:
Range value of the page #2
Bit
Identifier
Reset
Attr.
Function / Description
7dt0 XHIF_1_P2_RG_ROSL2 00h
r
Read only value = 0