Copyright © Siemens AG 2016. All rights reserved
289
ERTEC 200P-2 Manual
Technical data subject to change
Version 1.0
Register:
TIM_1_MODE_REG
Address:
20h
Bits:
31dt0
Reset value:
00000000h
Attributes: (r) (w)
Description:
Timer Mode Register for Timer 1
Bit
Identifier
Reset
Attr.
Function / Description
0
INIT_BIT
0h
w
Initialization (0 =INIT_BIT not active,
1 =INIT_BIT active)
3dt1 <reserved>
0h
not used
4
CLK_INPUT_SELECT
0h
r w
Selection of Count-/Load-Clock
0 =CLK_TIMT, 1 =ext. Gate-
/Triggersignal, see also bit
GATE_EFFECT)
5
RELOAD_DISABLE
0h
r w
Reload Mode disable
0 =Reload Mode is active, 1 =Single
Mode is active
6
DIS_RLD_WHEN_WR_LDREG 0h
r w
Disable Reload when Writimg Load-
Register
0 =Reload Mode is active, 1 =Single
Mode is active
7
EXT_GATE_TRIG_ENABLE 0h
r w
Selection of Gate-/Trigger signal
0 =INT_GATE_TRIG, 1
=EXT_GATE_TRIG is Gate-/Trigger
signal
8
GATE_POLARITY
0h
r w
polarity of ext. Gate/Trigger signal
0 =high active/rising edge, 1 =low
active/falling edge
9
GATE_EFFECT
0h
r w
Effect of ext. Gate/Trigger signal
0 =Gate-/Count-Mode for
CLK_INPUT_SELECT =0/1,1
=Trigger-/Toggle-Mode for
CLK_INPUT_SELECT =0/1
10
TIMER_OUT_POLARITY
0h
r w
polarity of TIM_OUT
0 =high active, 1 =low active
12dt11 EVENT1_CONTROL
0h
r w
Effect of EXT_EV1 on External Event
register
13
EVENT1_INVERSION
0h
r w
Inversion of Event1
0 =not inverted, 1 =inverted
15dt14 EVENT2_CONTROL
0h
r w
Effect of EXT_EV2 on External Event
register
16
EVENT2_INVERSION
0h
r w
Inversion of Event2
0 =not inverted, 1 =inverted
31dt17 <reserved>
0h
not used