Model 4200A-SCS Parameter Analyzer Reference Manual
Section 13: LPT library function reference
4200A-901-01 Rev. C / February 2017
13-3
Command
Description
Deletes all command definitions previously made with the
kibdefclr
(Keithley
GPIB define device clear) and
kibdefint
(Keithley GPIB define device initialize)
commands.
(on page 13-24) Defines a device-dependent command sent to an instrument connected to the GPIB
interface.
(on page 13-25)
Reads a device-dependent string from an instrument connected to the GPIB
interface.
(on page 13-26)
Sends a device-dependent command to an instrument connected to the GPIB
interface.
Serial polls an instrument connected to the GPIB interface.
(on page 13-28)
Synchronously serial polls an instrument connected to the GPIB interface.
(on page 13-28)
Configures and allocates a serial port for RS-232 communications.
(on page 13-
Defines a device-dependent character string sent to an instrument connected to a
serial port.
Deletes all command definitions previously made with the
kspdefclr
(Keithley
Serial Define Device Clear) and
kspdefint
(Keithley Serial Define Device
Initialize) commands.
(on page 13-
Defines a device-dependent character string sent to an instrument connected to a
serial port.
(on page 13-32)
Reads data from an instrument connected to a serial port.
(on page 13-32)
Sends a device-dependent command to an instrument attached to a RS-232 serial
port.
(on
page 13-33)
Posts double-precision floating point data from memory into the Clarius Analyze
sheet.
(on page 13-
Posts an integer-type data point from memory to the Clarius Analyze sheet in the
user test module and plots it on the graph.
Transfers a string from memory into the Clarius Analyze sheet in the user test
module and plots it on the graph.
(on page 13-35)
Sets a user-programmable delay.
(on page 13-36)
Returns the force array determined by the instrument action.
(on page 13-36)
Makes an averaging measurement for every point in a sweep.
(on page 13-
Makes a single measurement on multiple instruments at the same time.
(on page 13-38) Used to determine the voltage or current required to get a current or voltage.
(on page 13-42) Sets instrument-specific operating mode parameters.
(on page 13-44)
Makes an integrated measurement for every point in a sweep.
(on page 13-45) Allows a number of measurements to be made by a specified instrument during a
sweep
X
command. The results of the measurements are stored in the defined
array.
(on page 13-47) Causes a trigger when an instrument goes in or out of compliance.
Monitors for a predetermined level of voltage, current, or time.
(on page 13-50)
Deselects a test station.
(on page 13-50)
Enables or disables a test station.