Remote Control Commands
R&S
®
SMA100B
473
User Manual 1178.3834.02 ─ 03
Return values:
<IdList>
string
Comma-separated string of the parameter identifiers (
<Id>
)
Example:
See
Usage:
Query only
:SYSTem:SPECification:PARameter?
<Id>[, <Parameter>]
Retrieves data sheet information for a specific parameter.
Setting parameters:
<Id>
string
Identifies the name of the entry in the data sheet.
Query the data sheet parameters with the command
SPECification:IDENtification:CATalog?
<Parameter>
float
An additional value the result (
ValList
) depends on.
Return values:
<ValList>
float
Comma-separated list with the specified and, if available, the
typical value of the parameter, as specified in the data sheet.
Example:
Note:
The following values are merely an example. Your instru-
ment may not support the same parameters.
SYST:SPEC:PAR? "ID_RF_FREQ_SETTING_TIME_MS",0.1
SYST:SPEC:PAR? "ID_RF_LEVEL_MAX_GENERAL_DBM",
0.1
Usage:
Query only
:SYSTem:SPECification:VERSion:CATalog?
Queries all data sheet versions stored in the instrument.
Return values:
<VersCatalog>
string
Example:
See
Usage:
Query only
:SYSTem:SPECification:VERSion:FACTory?
Queries the data sheet version of the factory setting.
Return values:
<Version>
string
Example:
See
SYSTem Subsystem