Explanation:
An error occurred during a function or procedure call.
The cause of the error is indicated more closely by an error code.
The meaning of the error code can be found in the documentation of the function or procedure that caused the error.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program.
Programm
continuation:
Clear alarm with NC START or RESET key and continue the program.
14024
[Channel %1: ] Block %2 No access authorization for initialization of %3[%4].
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Variable to be reset
%4 = Index of the variable to be reset
Explanation:
When the function DELOBJ is called, an attempt is made to reset a variable to its default value. The access authorization
is not sufficient for this purpose.
When this alarm occurs, no data are changed, not even that for which the access authorization would be sufficient.
This alarm can only occur when the current value of the system variable, to which the attempt to write led to the alarm, is
not equal to its initial setting value.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Increase access authorization.
Programm
continuation:
Clear alarm with NC START or RESET key and continue the program.
14025
[Channel %1: ] Block %2 motion synchronous action: illegal modal ID
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
In modal motion synchronous actions an illegal ID number has been assigned.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Modify part program.
Programm
continuation:
Clear alarm with the RESET key. Restart part program
14026
[Channel %1: ] Block %2 motion synchronous action: invalid polynomial number in the FCTDEF
command
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
An FCTDEF command was programmed with a polynomial number that exceeds the maximum value set in MD28252
$MC_MM_NUM_FCTDEF_ELEMENTS.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Modify part program.
SINUMERIK 808D ADVANCED alarms
5.2 NCK alarms
Diagnostics Manual
Diagnostics Manual, 06/2015, 6FC5398-6DP10-0BA2
183