Explanation:
The specified axis reaches the working area limitation in JOG mode.
Reaction:
Alarm display.
Remedy:
Check SD43420 $SA_WORKAREA_LIMIT_PLUS and SD43430 $SA_WORKAREA_LIMIT_MINUS for the working area
limitation.
Programm
continuation:
Alarm display showing cause of alarm disappears. No further operator action necessary.
10632
[Channel %1: ] Block %2 axis %3 reaches the coordinate system-specific working area limit %4
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis, spindle number
%4 = String ( + or - )
Explanation:
The specified axis violates the coordinate system-specific working area limitation. This is not detected until the main run,
either because the minimum axis values could not be determined before the transformation or because there is an overlaid
movement.
Reaction:
Local alarm reaction.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm at block end.
Remedy:
Program other motion or do not perform overlaid motion.
Programm
continuation:
Clear alarm with the RESET key. Restart part program
10633
[Channel %1: ] Axis %2 is at coordinate system-specific working area limit %3%4
Parameters:
%1 = Channel number
%2 = Axis, spindle
%3 = String ( + or - )
%4 = The axis of the coordinate system-specific working area limitation is only output if different from the traversing axis.
Explanation:
The specified axis reaches the coordinate system-specific working area limitation in JOG mode.
Reaction:
Alarm display.
Remedy:
Check the system parameter $P_WORKAREA_CS_xx for the coordinate system-specific working area limitation.
Programm
continuation:
Alarm display showing cause of alarm disappears. No further operator action necessary.
10634
[Channel %1: ] Axis %2, tool radius compensation is inactive for type %3 working area limitation,
reason: The tool is not oriented parallel to the axis.
Parameters:
%1 = Channel number
%2 = Axis, spindle
%3 = 0: BCS, 1: WCS / SZS
Explanation:
The tool radius compensation of the working area limitation of the stated axis is not taken into account.
Reason: The tool is not oriented parallel to the axis (e.g. because toolcarrier or transformation is active).
The alarm is reported in JOG mode.
Reaction:
Alarm display.
Remedy:
The tool radius compensation for working area limitations in JOG mode can only be taken into account if the tool is parallel
to the axis.
Active transformation and toolcarrier must be switched off for this function.
Programm
continuation:
Clear alarm with the Delete key or NC START.
SINUMERIK 808D ADVANCED alarms
5.2 NCK alarms
Diagnostics Manual
Diagnostics Manual, 06/2015, 6FC5398-6DP10-0BA2
101