Explanation:
For PROFIBUS/PROFINET only:
The handwheel slot for handwheel %1 requested through machine data $MN_HANDWHEEL_INPUT is not available for
PROFIBUS handwheels.
Reaction:
Interface signals are set.
Alarm display.
Remedy:
Configure machine date MD11352 $MN_HANDWHEEL_INPUT to a valid handwheel slot for the corresponding PROFIBUS
handwheel.
Programm
continuation:
Switch control OFF - ON.
4632
Logical PROFIBUS handwheel slot base address for handwheel %1 not found
Parameters:
%1 = Handwheel number
Explanation:
For PROFIBUS/PROFINET only:
The logical basic address of the PROFIBUS handwheel slot in machine data array
$MN_HANDWHEEL_LOGIC_ADDRESS[] indexed in machine data $MN_HANDWHEEL_MODULE was not found in the
current STEP 7 hardware configuration.
Reaction:
Interface signals are set.
Alarm display.
Remedy:
Check if MD11351 $MN_HANDWHEEL_MODULE of the corresponding handwheel is correct. Check if indexed logical
base address of PROFIBUS handwheel slot in machine date array MD11353 $MN_HANDWHEEL_LOGIC_ADDRESS[]
is correct.
Programm
continuation:
Switch control OFF - ON.
4640
Invalid handwheel module for handwheel %1
Parameters:
%1 = Handwheel module
Explanation:
For ETHERNET only:
The handwheel module for handwheel %1 requested through MD11351 $MN_HANDWHEEL_MODULE is not available
for ETHERNET handwheels. MD11351 $MN_HANDWHEEL_MODULE = 1 must always be set when configuring
ETHERNET handwheels.
Reaction:
Interface signals are set.
Alarm display.
Remedy:
Set machine date MD11351 $MN_HANDWHEEL_MODULE = 1 for the corresponding handwheel.
Programm
continuation:
Switch control OFF - ON.
4641
Invalid handwheel input for handwheel %1
Parameters:
%1 = Handwheel input
Explanation:
For ETHERNET only:
The handwheel input for handwheel %1 requested through MD11352 $MN_HANDWHEEL_INPUT is not available for
ETHERNET handwheels. A maximum of 6 handwheels can be configured.
Reaction:
Interface signals are set.
Alarm display.
Remedy:
Configure MD11352 $MN_HANDWHEEL_INPUT for a valid input for the corresponding handwheel
Programm
continuation:
Switch control OFF - ON.
5000
Communication job not executable %1
Parameters:
%1 = Reference to which resources are no longer available.
Explanation:
The communication job (data exchange between NCK and HMI, e.g.: loading an NC part program) cannot be executed
because there is insufficient memory space. Cause: too many communication jobs in parallel.
Reaction:
Alarm display.
SINUMERIK 808D ADVANCED alarms
5.2 NCK alarms
Diagnostics Manual
78