22324
[Channel %1: ] Block %2 Axis %3 PRESETON or PRESETONS not permitted (cause: %4)
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis name, spindle number
%4 = Index describing the problem that occured in more detail
Explanation:
A problem has occurred when programming PRESETON or PRESETONS. This problem is described in more detail using
the "Index" parameter:
Index == 1: In MD30460 $MA_BASE_FUNCTION_MASK the PRESETON or PRESETONS function is deactivated.
Index == 2: For PRESETONS, the axis is monitored for collision. Actual value setting is not permitted.
Index == 3: PRESETON/PRESETONS is not permissible for synchronous GANTRY axes.
Index == 4: In speed control mode, PRESETON/PRESETONS is not permissible before terminating the traversing
movement.
Reaction:
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Apply the programming permitted.
Please notify the authorized personnel/service.
Programm
continuation:
Clear alarm with the RESET key. Restart part program
22400
[Channel %1: ] Option 'contour handwheel' not set
Parameters:
%1 = Channel number
Explanation:
The function 'contour handwheel' was activated without the neccesary option.
If the alarm occurs
- on selection of the contour handwheel via the PLC, then the contour handwheel has to be deselected in order to continue
with the program
- on account of programming FD=0, then the program can be corrected and continued with the compensation block and
NCSTART.
Reaction:
Alarm display.
Remedy:
Please inform the authorized personnel/service department.
- Set option
- Cancel the activation of the function 'contour handwheel'
- Modify part program.
Programm
continuation:
Clear alarm with the Delete key or NC START.
25000
Axis %1 hardware fault of active encoder
Parameters:
%1 = Axis name, spindle number
Explanation:
The signals of the currently active position actual value encoder (NC/PLC interface signal DB380x DBX1.5 = 1 (Position
measuring system 1) or DB380x DBX1.6 = 1 (Position measuring system 2)) are missing, do not have the same phase,
or exhibit grounding/short-circuit.
The alarm can be reprogrammed in the MD11412 $MN_ALARM_REACTION_CHAN_NOREADY (channel not ready).
For PROFIdrive only:
MD36310 $MA_ENC_ZERO_MONITORING >100 replaces the existing PowerOn alarm by the Reset alarm 25010.
SINUMERIK 808D ADVANCED alarms
5.2 NCK alarms
Diagnostics Manual
Diagnostics Manual, 06/2015, 6FC5398-6DP10-0BA2
337