Programm
continuation:
Clear alarm with the Delete key or NC START.
22011
[Channel %1: ] Block %3 spindle %2 change to programmed gear stage not possible
Parameters:
%1 = Channel number
%2 = Spindle number
%3 = Block number, label
Explanation:
With the 'DryRun', 'ProgramTest' and 'SearchRunByProgTest' functions deselected, it is not possible in the Repos module
to carry out a gear stage change to a previously programmed gear stage. This is the case, if the spindle is in the deselection
block not active in speed control mode, as a slave axis or in a transformation. Execution of a gear stage change is avoided
if the above mentioned functions are deselected by resetting bit 2 of MD35035 $MA_SPIND_FUNCTION_MASK.
Reaction:
Alarm display.
Remedy:
Change deselection block or block search target block to speed control mode (M3, M4, M5, SBCOF). Set bit 2 of MD35035
$MA_SPIND_FUNCTION_MASK to 0.
Programm
continuation:
Clear alarm with the Delete key or NC START.
22020
[Channel %1: ] Block %3 spindle %2 gear step change position not reached
Parameters:
%1 = Channel number
%2 = Spindle number
%3 = Block number, label
Explanation:
Through the configuration of MD35010 $MA_GEAR_STEP_CHANGE_ENABLE[AXn] = 2, the spindle is traversed to the
position stored in MD35012 $MA_GEAR_STEP_CHANGE_POSITION[AXn] before the actual gear step change. The
required gear step change position has not been reached.
Reaction:
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Correct sequence in the PLC.
Programm
continuation:
Clear alarm with the RESET key. Restart part program
22022
[Channel %1: ] Block %2 spindle %3 gear stage %4 is expected for axis mode.
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Spindle
%4 = Gear stage
Explanation:
The gear stage required for axis mode has not been installed.
A gear stage has been configured in MD35014 $MA_GEAR_STEP_USED_IN_AXISMODE, in which the spindle is to be
in axis mode. This gear stage is checked whenever the spindle is switched into axis mode. The configured gear stage is
compared with the gear stage output by the PLC (NC/PLC interface signal DB380x DBX2000.0 - .2 (Actual gear stage A
through C)).
This alarm will be output if the gear stages are not the same.
Reaction:
Interface signals are set.
Alarm display.
Remedy:
Program M70 before the switch to axis mode. The gear stage configured in MD35014
$MA_GEAR_STEP_USED_IN_AXISMODE is then automatically loaded.
No gear stage change is required if the configured gear stage is aleady active. M40 remains active beyond the gear stage
change.
Consider MD20094 $MC_SPIND_RIGID_TAPPING_M_NR.
Programm
continuation:
Clear alarm with the Delete key or NC START.
SINUMERIK 808D ADVANCED alarms
5.2 NCK alarms
Diagnostics Manual
Diagnostics Manual, 06/2015, 6FC5398-6DP10-0BA2
327