Explanation:
Processing of motion-synchronous actions requires resources that are configured using MD28060
$MC_MM_IPO_BUFFER_SIZE, MD28070 $MC_MM_NUM_BLOCKS_IN_PREP, MD28251
$MC_MM_NUM_SAFE_SYNC_ELEMENTS, MD28250 $MC_MM_NUM_SYNC_ELEMENTS, and MD28253
$MC_MM_NUM_SYNC_STRINGS. If these resources are insufficient for the execution of the part program, then this alarm
is issued. Parameter %3 shows which resource has run out:
Increase identifier <= 2: MD28060 $MC_MM_IPO_BUFFER_SIZE or
MD28070 $MC_MM_NUM_BLOCKS_IN_PREP.
Increase identifier > 2: MD28250 $MC_MM_NUM_SYNC_ELEMENTS, MD28251
$MC_MM_NUM_SAFE_SYNC_ELEMENTS.
Increase identifier 7: MD28253 $MC_MM_NUM_SYNC_STRINGS.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Correct part program or increase resources.
Programm
continuation:
Clear alarm with NC START or RESET key and continue the program.
14752
[Channel %1: ] Block %2 DELDTG | STOPREOF conflict
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
In a block of motion synchronous actions referring to a motion block, both DELDTG (delete distance-to-go) and STOPREOF
(preprocessing stop) have been programmed.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
The functions DELDTG and STOPREOF exclude each other in a block.
Programm
continuation:
Clear alarm with NC START or RESET key and continue the program.
14753
[Channel %1: ] Block %2 motion synchronous action: %3 illegal interpolation type
Parameters:
%1 = Channel number
%2 = Block number, line number
%3 = Synact ID
Explanation:
The active interpolation type (e.g. 5-axis interpolation) is not allowed for the motion synchronous action or for the function
"Several feeds".
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Modify part program.
Programm
continuation:
Clear alarm with NC START or RESET key and continue the program.
14754
[Channel %1: ] Block %2 motion synchronous action: %3 wrong feed type
Parameters:
%1 = Channel number
%2 = Block number, line number
%3 = Synact ID
Explanation:
The active feed type is not allowed for the motion synchronous action or for the function "Several feeds".
SINUMERIK 808D ADVANCED alarms
5.2 NCK alarms
Diagnostics Manual
Diagnostics Manual, 06/2015, 6FC5398-6DP10-0BA2
217