Explanation:
Incorrect programming:
This channel does not recognize the spindle number.
The alarm can occur together with a dwell or a spindle function.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Please inform the authorized personnel/service department.
Check the part program to determine whether the programmed spindle number is correct and whether the program is run
in the correct channel.
Check MD35000 $MA_SPIND_ASSIGN_TO_MACHAX for all machine axes to see whether one of them contains the
programmed spindle number. This machine axis number must be entered in a channel axis of the machine data MD20070
$MC_AXCONF_MACHAX_USED.
Programm
continuation:
Clear alarm with NC START or RESET key and continue the program.
16105
[Channel %1: ] Block %2 spindle %3 cannot be assigned
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = String
Explanation:
Mistake in programming: The programmed spindle is not assigned a real spindle by the spindle number converter. The
alarm can be issued after improper use of SD42800 $SC_SPIND_ASSIGN_TAB[].
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Correct setting data or modify part program.
Programm
continuation:
Clear alarm with the RESET key. Restart part program
16111
[Channel %1: ] Block %2 spindle %3 No speed programmed
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Spindle
Explanation:
Programming of a speed is expected.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Program speed with S[spindle number]=..
Programm
continuation:
Clear alarm with NC START or RESET key and continue the program.
16200
[Channel %1: ] Block %2 spline and polynominal interpolation not available
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
The spline and polynomial interpolation are options that are not contained in the basic version of the control.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Do not program spline and polynomial interpolation, or retrofit the necessary option.
Programm
continuation:
Clear alarm with NC START or RESET key and continue the program.
SINUMERIK 808D ADVANCED alarms
5.2 NCK alarms
Diagnostics Manual
244
Diagnostics Manual, 06/2015, 6FC5398-6DP10-0BA2