61855
[Channel %1: ] Block %2: Target point lies in the retraction area
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
The specified target point lies in the retraction area.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Change target point or retraction area.
Programm
continuation:
Clear alarm with the RESET key. Restart part program
61856
[Channel %1: ] Block %2: Absolute input of the work offset values not enabled
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
The absolute input of the work offset value has not been enabled.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
52212 $MCS_FUNCTION_MASK_TECH Bit 6: work offset value WO cannot be entered as absolute value (ShopTurn).
Programm
continuation:
Clear alarm with the RESET key. Restart part program
61857
[Channel %1: ] Block %2: No rotary axis to accept a blank has been set up
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
No rotary axis to accept a blank has been set up.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Check MD52207 $MCS_AXIS_USAGE_ATTRIB bit 8.
Programm
continuation:
Clear alarm with the RESET key. Restart part program
61858
[Channel %1: ] Block %2: Turning is only possible with a blank that is clamped, centered
Parameters:
%1 = Channel number
%2 = Block number, label
Explanation:
Turning is only possible with a blank that is clamped, centered.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Use a blank that is clamped so that it is centered.
Programm
continuation:
Clear alarm with the RESET key. Restart part program
SINUMERIK 808D ADVANCED alarms
5.3 Cycle alarms
Diagnostics Manual
Diagnostics Manual, 06/2015, 6FC5398-6DP10-0BA2
487