User Manual
UMN:CLI
V8102
777
A.B.C.D
{
netmask
<1-32> |
cos
<0-7>}
To display the configured CoS remarking information of ONU ID, use the following com-
mand.
Command
Mode
Description
show
onu
cos-remarking
[
gpon ONU_ID
]
Enable
Global
Interface
[GPON]
Shows the CoS remarking information of ONU.
show
onu
cos-remarking
[
gpon ONU_ID
]
Shows the CoS remarking of ONU configured on
an OLT.
13.2.19
ONU Authentication from RADIUS server
You can use the RADIUS authentication process when an ONU (ONT) is activated and it
attempts to access an OLT. The RADIUS Access-Request message is sent from the OLT
to the RADIUS server. If the ONU is valid, the RADIUS server consults a database of
ONUs to find the ONU which matches the authentication attributes in the connection re-
quest. If the RADIUS server has the valid ONU-related information, it sends the configu-
ration settings placed into a RADIUS Access-Accept message to the OLT for the ONU
registration. The OLT receives the service profile settings from the RADIUS server and it
assigns a new service profile to ONU.
RADIUS Authentication Process
①
Upload MIB Info
: During the initial connection between OLT and ONU, the ONU up-
loads the MIB information. On the OLT side, the OLT checks the ONU validation us-
ing ONU model name, firmware version and serial number.
②
Sends RADIUS message
: If the RADIUS authentication is required when the OLT
and ONU are connected each other, the OLT sends Access-Request message with
the authentication attributes (user name, user password, OLT-ID, ONU-ID, ONT
model name, serial number, firmware version) to the RADIUS server.
③
Receive Response message
: If the RADIUS message is sent by a valid ONU, and if
the authentication attributes contain the correct values, the Access-Accept message
of ONU configuration settings is sent by the RADIUS server.
④
Set the configuration
: The OLT receives the service profile information from the