User Manual
UMN:CLI
V8102
107
The console port settings are:
• 9600 baud rate
• 8 data bits
• 1 stop bit
• No parity
• No flow control
2. Connect a terminal or PC with terminal-emulation software to the console port on the
SFU module. At your terminal, booting will be automatically started and login prompt
will be displayed. By default setting, the user name is configured as
admin
. At the
password prompt, press [
ENTER
].
3. Open the
MGMT Interface Configuration
Mode. And assign an IP address and
subnetwork mask for the management interface.
4. Configure a management route to the network from which you are accessing the
system.
5. Save the IP settings so that they will be in effect after the next system reboot by
reload
command.
6. Once you have completed the proper hardware installation and initial software
configuration for the V8102, you can access the system remotely by Telnet.
The following is an example of accessing the system remotely.
SWITCH login:
admin
Password:
SWITCH>
enable
SWITCH#
configure terminal
SWITCH(config)#
interface management
SWITCH(config-if[mgmt])#
ip address 10.55.192.161/24
SWITCH(config-if[mgmt])#
no shutdown
SWITCH(config-if[mgmt])#
write memory
[OK]
SWITCH(config-if[mgmt])#
exit
SWITCH(config)#
ip route 10.55.0.0/16 10.55.192.254
SWITCH(config)#
write memory
[OK]
SWITCH(config)#
show ip interface brief
Interface Status Protocol Primary IP Secondary IP
------------------------------------------------------------------------------
mgmt up up 10.55.192.161 unassigned
SWITCH(config)#
exit
SWITCH#
reload