8400 StateLine C | Reference manual
Parameter reference
Parameter list | C00821
648
L
Firmware
≤
11.00 - DMS 8.0 EN - 10/2011
C00821
C00828
C00829
Parameter | Name:
C00821 | L_DigitalLogic_1: Truth table
Data type: UNSIGNED_8
Index: 23754
d
= 5CCA
h
The
L_DigitalLogic_1
FB: Parameterisation of the truth table
Selection list
0 False
1 TRUE
Subcodes
Lenze setting
Info
C00821/1
0: FALSE
L_DigitalLogic_1
: bIn3...bIn1=0 0 0
C00821/2
0: FALSE
L_DigitalLogic_1
: bIn3...bIn1=0 0 1
C00821/3
0: FALSE
L_DigitalLogic_1
: bIn3...bIn1=0 1 0
C00821/4
0: FALSE
L_DigitalLogic_1
: bIn3...bIn1=0 1 1
C00821/5
0: FALSE
L_DigitalLogic_1
: bIn3...bIn1=1 0 0
C00821/6
0: FALSE
L_DigitalLogic_1
: bIn3...bIn1=1 0 1
C00821/7
0: FALSE
L_DigitalLogic_1
: bIn3...bIn1=1 1 0
C00821/8
0: FALSE
L_DigitalLogic_1
: bIn3...bIn1=1 1 1
;
Read access
;
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C00828 | L_DigitalLogic_3: Function
Data type: UNSIGNED_8
Index: 23747
d
= 5CC3
h
From version 11.00.00
The
L_DigitalLogic_3
FB: Selection of the internal logic function
Selection list
(Lenze setting printed in bold)
Info
0 bOut = 0
Constant value "FALSE"
1 bOut = 1
Constant value "TRUE"
2 bOut = bIn1 AND bIn2 AND bIn3
AND operation
3 bOut = bIn1 OR bIn2 OR bIn3
OR operation
4 bOut = f (truth table)
The truth table parameterised in
C00829
is used.
;
Read access
;
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C00829 | L_DigitalLogic_3: Truth table
Data type: UNSIGNED_8
Index: 23746
d
= 5CC2
h
From version 11.00.00
The
L_DigitalLogic_3
FB: Parameterisation of the truth table
Selection list
0 False
1 TRUE
Subcodes
Lenze setting
Info
C00829/1
0: FALSE
L_DigitalLogic_3
: bIn3...bIn1=0 0 0
C00829/2
0: FALSE
L_DigitalLogic_3
: bIn3...bIn1=0 0 1
C00829/3
0: FALSE
L_DigitalLogic_3
: bIn3...bIn1=0 1 0
C00829/4
0: FALSE
L_DigitalLogic_3
: bIn3...bIn1=0 1 1
C00829/5
0: FALSE
L_DigitalLogic_3
: bIn3...bIn1=1 0 0
C00829/6
0: FALSE
L_DigitalLogic_3
: bIn3...bIn1=1 0 1
C00829/7
0: FALSE
L_DigitalLogic_3
: bIn3...bIn1=1 1 0
C00829/8
0: FALSE
L_DigitalLogic_3
: bIn3...bIn1=1 1 1
;
Read access
;
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1