8400 StateLine C | Reference manual
Function library
Function blocks | L_JogCtrlExtension_1
808
L
Firmware
≤
11.00 - DMS 8.0 EN - 10/2011
Outputs
Truth table
[16-1] Truth table for activating the pre-switch off
Identifier
Data type
Value/meaning
bRfgOut
BOOL
Control signal for ramping down the setpoint generator
• Connect this output to the
bRfg0
input of the
L_NSet
FB.
bJog1Out
BOOL
Control signal for setting fixed speeds in the setpoint generator
• Connect this output to the
bJog1
input of the
L_NSet
FB.
bJog2Out
BOOL
Control signal for setting fixed speeds in the setpoint generator
• Connect this output to the
bJog2
input of the
L_NSet
FB.
Input
Function
Response in the L_NSet FB
bInputSel1
bInputSel2
FALSE
FALSE
Pre-switch off inactive
No response
• The
bRfgIn
input signal is directly output
at the
bRfgOut
output.
• The
bJogIn1
and
bJogIn2
input signals are
directly output at the
bJog1Out
and
bJog2Out
outputs.
TRUE
FALSE
The
bSlowDown1
and
bStop1
inputs
are evaluated.
Pre-switch off can be activated
• If the SlowDown function is activated via
the selected
bSlowDown
input, fixed
setpoint 2 in the setpoint generator is
activated via the
bJog1Out
and
bJog2Out
outputs.
• If the Stop function is activated via the
selected
bStop
input, the
bRfgOut
output
is set to TRUE and hence the setpoint
generator is deactivated.
FALSE
TRUE
The
bSlowDown2
and
bStop2
inputs
are evaluated.
TRUE
TRUE
The
bSlowDown3
and
bStop3
inputs
are evaluated.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com