CHAPTER 8 ESC/POS MODE (INTERFACE COMMANDS)
B-EP
Series
8-42
(5) At a moment when an error occurs with parameter xL to dyH due to a factor such as
an unmatched condition, command processing will be aborted, and the data
subsequent to dyH will be processed as normal data.
(6) If the following commands, which are used commonly among the B-EP series, are
received, a higher priority will be given to them. Therefore, the same range as
these commands cannot be specified.
[ESC] WS [LF] [NUL]
[ESC] WT [LF] [NUL]
[ESC] WB [LF] [NUL]
[ESC] WR [LF] [NUL]
[ESC] WW [LF] [NUL]
(Example)
[ESC] W
xL xH yL yH dxL dxH dyL dyH
↓
↓
↓
↓
↓
↓
↓
↓
S 10 0 0 160 1 160 1
The above values are specified. If inputted in hex format, they are as follows:
[1BH][57H][53H][0AH][00H][00H][A0H][01H][A0H][01H]
However the underlined portion is considered as [ESC] WS [LF] [NUL].
Therefore, a priority is given to the Status Request Command rather than the Page
Mode Print Area Set Command.
(7) The figure below illustrates a print area with the starting point in the horizontal
direction X, starting point in the vertical direction Y, length in the horizontal direction
Dx, and length in the vertical direction Dy.
Print area
Dx
Dy
(X, Y)
(X + Dx - 1, Y + Dy - 1)
Paper feed direction