Command Manual (For Soliton) – AAA
H3C S3100 Series Ethernet Switches
Chapter 1 AAA Configuration Commands
1-62
Related commands:
radius scheme
,
retry
.
Examples
# Set the timeout time of the response timeout timer for RADIUS scheme radius1 to 5
seconds.
<Sysname> system-view
System View: return to User View with Ctrl+Z.
[Sysname] radius scheme radius1
New Radius scheme
[Sysname-radius-radius1] timer 5
1.2.30 timer quiet
Syntax
timer quiet minutes
undo timer quiet
View
RADIUS scheme view
Parameters
minutes
: Wait time before primary server state restoration, ranging from 1 to 255
minutes.
Description
Use the
timer quiet
command to set the time that the switch waits before it tries to
re-communicate with the primary server and restore the status of the primary server to
active.
Use the
undo timer quiet
command to restore the default wait time.
By default, the switch waits five minutes.
Related commands:
display radius scheme
.
Examples
# Configure the switch to wait 10 minutes before it tries to restore the status of the
primary server to active.
<Sysname> system-view
System View: return to User View with Ctrl+Z.
[Sysname] radius scheme radius1
New Radius scheme
[Sysname-radius-radius1] timer quiet 10