Command Manual (For Soliton) – Information Center
H3C S3100 Series Ethernet Switches
Chapter 1 Information Center Configuration
Commands
1-12
<Sysname> system-view
System View: return to User View with Ctrl+Z.
[Sysname] info-center loghost source Vlan-interface 1
1.1.12 info-center monitor channel
Syntax
info-center monitor channel
{
channel
-
number | channel
-
name
}
undo info-center monitor channel
View
System view
Parameter
channel
-
number
: Channel number, ranging from 0 to 9, corresponding to the 10
channels of the system.
channel
-
name
: Channel name, by default, the name of channel 0 to channel 9 is (in turn)
console
,
monitor
,
loghost
,
trapbuffer
,
logbuffer
,
snmpagent
,
channel6
,
channel7
,
channel8
,
channel9
.
Description
Use the
info-center monitor channel
command to set the channel through which
information is output to user terminals.
Use the
undo info-center monitor channel
command to restore the default channel
through which information is output to user terminals.
By default, output of system information to the monitor is enabled with a default channel
name of monitor and a default channel number of 1.
This command works only when the information center is enabled.
Related command:
info-center enable
,
display info-center
.
Example
# Set the system to output information to user terminals through channel 0.
<Sysname> system-view
System View: return to User View with Ctrl+Z.
[Sysname] info-center monitor channel 0
1.1.13 info-center snmp channel
Syntax
info-center snmp channel
{
channel
-
number | channel
-
name
}