The multi-word programming flow is shown in Figure 6.4-13. The starting ISP address
(FMC_ISPADDR) has to be 16-byte align, FMC_ISPADDR[3:0] should be 0. FMC_MPDAT0 is the
data word of the offset 0x0, FMC_MPDAT1 is the second word (offset 0x4), FMC_MPDAT2 is the
third word (offset 0x8), and FMC_MPDAT3 is forth word (offset 0xC). If the starting ISP address
FMC_ISPADDR [3] is 0, the 1
st
data word should put on FMC_MPDAT0, and 2
nd
word is
FMC_MPDAT1, 3
rd
word is FMC_MPDAT2, and 4
th
word is FMC_MPDAT3. If the starting ISP
address FMC_ISPADDR [3] is 1, the 1
st
data word should put on FMC_MPDAT2, and 2
nd
word is
FMC_MPDAT3, 3
rd
word is FMC_MPDAT0, and 4
th
word is FMC_MPDAT1. The maximum
programming size is 512 bytes and aligns to 512-byte address. While FMC controller performs
multi-word programming operation, CPU needs to monitor the buffer status D3~D0
(FMC_MPSTS[7:4]) and MPBUSY (FMC_MPSTS[0]) to wait the buffer empty ((D1,D0)=00, or
(D3,D2)=00), and then CPU needs to update the next programming data (FMC_MPDAT0,
FMC_MPDAT1, FMC_MPDAT2 and FMC_MPDAT3) in time. Otherwise, FMC controller will exit
multi-word programming operation (MPBUSY (FMC_MPSTS[0]) = 0). If CPU cannot update the
data in time (MPBUSY (FMC_MPSTS[0]) =0), CPU needs restart a new multi-word programming
procedure to continue, FMC_MPADDR provides the last program address information. At the end
of operation, CPU has to check ISPFF (FMC_MPSTS[2]) to confirm the multi-word operation
successful complete.