ISD94100 Series Technical Reference Manual
Sep 9, 2019
Page
459
of 928
Rev1.09
IS
D
9
410
0
S
ER
IE
S
T
E
C
HN
ICA
L
RE
F
E
RE
NCE
M
AN
U
AL
PWM Dead-time Control Register 0_1, 2_3, 4_5 (PWM_DTCTL0_1, 2_3, 4_5)
Register
Offset
R/W Description
Reset Value
PWM_DTCTL0_1
0x70
R/W PWM Dead-Time Control Register 0/1
0x0000_0000
PWM_DTCTL2_3
0x74
R/W PWM Dead-Time Control Register 2/3
0x0000_0000
PWM_DTCTL4_5
0x78
R/W PWM Dead-Time Control Register 4/5
0x0000_0000
31
30
29
28
27
26
25
24
Reserved
DTCKSEL
23
22
21
20
19
18
17
16
Reserved
DTEN
15
14
13
12
11
10
9
8
Reserved
DTCNT
7
6
5
4
3
2
1
0
DTCNT
Bits
Description
[31:25]
Reserved
Reserved. Any values read should be ignored. When writing to this field always write with
reset value.
[24]
DTCKSEL
Dead-time Clock Select (Write Protected)
0 = Dead-time clock source from PWM_CLK.
1 = Dead-time clock source from prescaler output.
Note:
This register is write protected. Refer to SYS_REGLCTL register.
[23:17]
Reserved
Reserved. Any values read should be ignored. When writing to this field always write with
reset value.
[16]
DTEN
Enable Dead-time Insertion for PWM Pair (PWM_CH0, PWM_CH1) (PWM_CH2,
PWM_CH3) (PWM_CH4, PWM_CH5) (Write Protected)
Dead-time insertion is only active when this pair of complementary PWM is enabled. If dead-
time insertion is inactive, the outputs of pin pair are complementary without any delay.
0 = Dead-time insertion Disabled on the pin pair.
1 = Dead-time insertion Enabled on the pin pair.
Note:
This register is write protected. Refer to SYS_REGLCTL register.
[15:12]
Reserved
Reserved. Any values read should be ignored. When writing to this field always write with
reset value.
[11:0]
DTCNT
Dead-time Counter (Write Protected)
The dead-time can be calculated from the following formula:
Dead-time = (DTCNT[11:0]+1) * PWM_CLK period.
Note: