ISD94100 Series Technical Reference Manual
Sep 9, 2019
Page
445
of 928
Rev1.09
IS
D
9
410
0
S
ER
IE
S
T
E
C
HN
ICA
L
RE
F
E
RE
NCE
M
AN
U
AL
1 = PERIOD will load to PBUF at the end point of each period. CMPDAT will load to
CMPBUF at the end point of each period when valid reload window is set. The valid reload
window is set by software write 1 to PWM_LOAD register and cleared by hardware after
load success.
[10]
WINLDEN2
PWM Channel 2 Window Load Enable Bits
0 = PERIOD will load to PBUF at the end point of each period. CMPDAT will load to
CMPBUF at the end point or center point of each period by setting CTRLD bit.
1 = PERIOD will load to PBUF at the end point of each period. CMPDAT will load to
CMPBUF at the end point of each period when valid reload window is set. The valid reload
window is set by software write 1 to PWM_LOAD register and cleared by hardware after
load success.
[9]
WINLDEN1
PWM Channel 1 Window Load Enable Bits
0 = PERIOD will load to PBUF at the end point of each period. CMPDAT will load to
CMPBUF at the end point or center point of each period by setting CTRLD bit.
1 = PERIOD will load to PBUF at the end point of each period. CMPDAT will load to
CMPBUF at the end point of each period when valid reload window is set. The valid reload
window is set by software write 1 to PWM_LOAD register and cleared by hardware after
load success.
[8]
WINLDEN0
PWM Channel 0 Window Load Enable Bits
0 = PERIOD will load to PBUF at the end point of each period. CMPDAT will load to
CMPBUF at the end point or center point of each period by setting CTRLD bit.
1 = PERIOD will load to PBUF at the end point of each period. CMPDAT will load to
CMPBUF at the end point of each period when valid reload window is set. The valid reload
window is set by software write 1 to PWM_LOAD register and cleared by hardware after
load success.
[7:6]
Reserved
Reserved. Any values read should be ignored. When writing to this field always write with
reset value.
[5]
CTRLD5
PWM Channel 5 Center Re-load
In up-down counter type, PERIOD will load to PBUF at the end point of each period.
CMPDAT will load to CMPBUF at the center point of a period.
[4]
CTRLD4
PWM Channel 4 Center Re-load
In up-down counter type, PERIOD will load to PBUF at the end point of each period.
CMPDAT will load to CMPBUF at the center point of a period.
[3]
CTRLD3
PWM Channel 3 Center Re-load
In up-down counter type, PERIOD will load to PBUF at the end point of each period.
CMPDAT will load to CMPBUF at the center point of a period.
[2]
CTRLD2
PWM Channel 2 Center Re-load
In up-down counter type, PERIOD will load to PBUF at the end point of each period.
CMPDAT will load to CMPBUF at the center point of a period.
[1]
CTRLD1
PWM Channel 1 Center Re-load
In up-down counter type, PERIOD will load to PBUF at the end point of each period.
CMPDAT will load to CMPBUF at the center point of a period.
[0]
CTRLD0
PWM Channel 0 Center Re-load
In up-down counter type, PERIOD will load to PBUF at the end point of each period.
CMPDAT will load to CMPBUF at the center point of a period.