ISD94100 Series Technical Reference Manual
Sep 9, 2019
Page
486
of 928
Rev1.09
IS
D
9
410
0
S
ER
IE
S
T
E
C
HN
ICA
L
RE
F
E
RE
NCE
M
AN
U
AL
Note1:
If CMPDAT equal to PERIOD, this flag is not working in down counter type selection.
Note2:
In complementary mode, CMPDIF1, 3, 5 use as another CMPDIF for channel 0, 2,
4.
[24]
CMPDIF0
PWM Channel 0 Compare Down Count Interrupt Flag
Flag is set by hardware when PWM counter down count and reaches PWM_CMPDAT0,
software can clear this bit by writing 1 to it.
Note1:
If CMPDAT equal to PERIOD, this flag is not working in down counter type selection.
Note2:
In complementary mode, CMPDIF1, 3, 5 use as another CMPDIF for channel 0, 2,
4.
[23:22]
Reserved
Reserved. Any values read should be ignored. When writing to this field always write with
reset value.
[21]
CMPUIF5
PWM Channel 5 Compare Up Count Interrupt Flag
Flag is set by hardware when PWM counter up count and reaches PWM_CMPDAT5,
software can clear this bit by writing 1 to it.
Note1:
If CMPDAT equal to PERIOD, this flag is not working in up counter type selection.
Note2:
In complementary mode, CMPUIF1, 3, 5 use as another CMPUIF for channel 0, 2,
4.
[20]
CMPUIF4
PWM Channel 4 Compare Up Count Interrupt Flag
Flag is set by hardware when PWM counter up count and reaches PWM_CMPDAT4,
software can clear this bit by writing 1 to it.
Note1:
If CMPDAT equal to PERIOD, this flag is not working in up counter type selection.
Note2:
In complementary mode, CMPUIF1, 3, 5 use as another CMPUIF for channel 0, 2,
4.
[19]
CMPUIF3
PWM Channel 3 Compare Up Count Interrupt Flag
Flag is set by hardware when PWM counter up count and reaches PWM_CMPDAT3,
software can clear this bit by writing 1 to it.
Note1:
If CMPDAT equal to PERIOD, this flag is not working in up counter type selection.
Note2:
In complementary mode, CMPUIF1, 3, 5 use as another CMPUIF for channel 0, 2,
4.
[18]
CMPUIF2
PWM Channel 2 Compare Up Count Interrupt Flag
Flag is set by hardware when PWM counter up count and reaches PWM_CMPDAT2,
software can clear this bit by writing 1 to it.
Note1:
If CMPDAT equal to PERIOD, this flag is not working in up counter type selection.
Note2:
In complementary mode, CMPUIF1, 3, 5 use as another CMPUIF for channel 0, 2,
4.
[17]
CMPUIF1
PWM Channel 1 Compare Up Count Interrupt Flag
Flag is set by hardware when PWM counter up count and reaches PWM_CMPDAT1,
software can clear this bit by writing 1 to it.
Note1:
If CMPDAT equal to PERIOD, this flag is not working in up counter type selection.
Note2:
In complementary mode, CMPUIF1, 3, 5 use as another CMPUIF for channel 0, 2,
4.
[16]
CMPUIF0
PWM Channel 0 Compare Up Count Interrupt Flag
Flag is set by hardware when PWM counter up count and reaches PWM_CMPDAT0,
software can clear this bit by writing 1 to it.
Note1:
If CMPDAT equal to PERIOD, this flag is not working in up counter type selection.
Note2:
In complementary mode, CMPUIF1, 3, 5 use as another CMPUIF for channel 0, 2,
4.
[15:14]
Reserved
Reserved. Any values read should be ignored. When writing to this field always write with
reset value.