ISD94100 Series Technical Reference Manual
Sep 9, 2019
Page
75
of 928
Rev1.09
IS
D
9
410
0
S
ER
IE
S
T
E
C
HN
ICA
L
RE
F
E
RE
NCE
M
AN
U
AL
Brown-out Detector Control Register (SYS_BODCTL)
Part of the SYS_BODCTL control registers values are initialized by flash configuration and writeable bits
are write-protected.
Register
Offset
R/W Description
Reset Value
SYS_BODCTL
0x18
R/W Brown-Out Detector Control Register
0x000X_038X
31
30
29
28
27
26
25
24
Reserved
23
22
21
20
19
18
17
16
Reserved
BODVL
15
14
13
12
11
10
9
8
Reserved
BODDGSEL
7
6
5
4
3
2
1
0
LVREN
BODOUT
BODLPM
BODIF
BODRSTEN
Reserved
BODEN
Bits
Description
[31:19]
Reserved
Reserved. Any values read should be ignored. When writing to this field always write with
reset value.
[18:16]
BODVL
Brown-out Detector Threshold Voltage Selection (Write Protected)
The default value is set by flash controller user configuration register CBOV (CONFIG0
[23:21]).
000 = Brown-Out Detector threshold voltage is 1.6V.
001 = Brown-Out Detector threshold voltage is 1.8V.
010 = Brown-Out Detector threshold voltage is 2.0V.
011 = Brown-Out Detector threshold voltage is 2.2V.
100 = Brown-Out Detector threshold voltage is 2.4V.
101 = Brown-Out Detector threshold voltage is 2.6V.
110 = Brown-Out Detector threshold voltage is 2.8V.
111 = Brown-Out Detector threshold voltage is 3.0V.
Note:
These bits are write protected. Refer to the SYS_REGLCTL register.
[15:11]
Reserved
Reserved. Any values read should be ignored. When writing to this field always write with
reset value.
[10:8]
BODDGSEL
Brown-out Detector Output De-glitch Time Select (Write Protected)
000 = Without de-glitch function.
001 = 3 system clock (HCLK).
010 = 7 system clock (HCLK).
011 = 15 system clock (HCLK).
100 = 31 system clock (HCLK).
101 = 63 system clock (HCLK).
110 = 127 system clock (HCLK).
111 = 255 system clock (HCLK).
Note:
These bits are write protected. Refer to the SYS_REGLCTL register.